CLS Open Source Software

Source code for open source files are available for download from: http://exshare.lightsource.ca/OpenSource.

CLS makes extensive use of EPICS software from other facilities. As part of the international EPICS collaboration, CLS also makes EPICS software available to other institutions. These drivers are used extensively in the CLS Accelerator and Beamline Control System.

EPICS RS-232 Drivers

EPICS RS-232/485 drivers are based on the use on the use of a the generic ASCII serial line driver.

Driver

Status

Contact

Documentation

Canberra ADM-606MC Portable Digital Multi-function Radiation Meter

In use as area monitors.

Tony Wilson

To be added

Danfysik System 8000 Series Magnet Power Supplies

In use on BR1 and magnet mapping facility.

Glen Wright

To be added

Granville-Phillips GP375 Convectron Vacuum Gage

In use on beamlines and front-ends.

Glen Wright

To be added

Health Physics Instruments HPI 2010 Ionization Chamber Monitor

In use as special purpose monitors.

Tony Wilson

To be added

Health Physics Instruments HPI 2080 Pulse Neutron Monitor

In use as special purpose monitors.

Tony Wilson

To be added

IE Power CLS Custom Magnet Power Supplies

In use on BTS and SR1.

Glen Wright

To be added

Keithley 2000 Series Volt Meter

In use on SR1 PCT and magnet mapping facility.

Tony Wilson

To be added

Keithley 6485 pA-meter

In use on all beamlines.

Tony Wilson

To be added

Kontrol RPM-PLUS Power Switch

In use for timing system

Glen Wright

To be added

MicroImage Video Systems CL741 Four Line CrossLine Generator

In use on Linac and LTB1.

Hao Zhang

To be added

National Instruments FP-1000 series Field Point Distributed IO (support for FP-TC-120, FP-RTD-122, FP-RLY-420, FP-DI-301, FP-DI-330, FP-DI-401)

In use on Linac, SR1, and CMCF, HXMA beamlines.

Tony Wilson

To be added

Ontrack Control Systems AVR8000 Video Switch

In use on Linac.

Hao Zhang

To be added

Puls-Plasmatechnik CLS Custom Kicker Pulsed Power Supplies (2kV to 23kV)

In use on BR1 Injection, BR1 Extraction and SR1 Injection.

Glen Wright

To be added

Varian Dual and MidiVac Controller VacIon Power Supply

In use on BR1, BTS, SR1, and all beamlines.

Glen Wright

To be added

EPICS GPIB Drivers

Driver

Status

Contact

Documentation

Agilent Technologies 66000A Modular Power Supply System /w 66102A and a 66105A

In use on SR1 insertion device corrector coils

Tony Wilson

To be added

EPICS VME Drivers

VME crates are normally controlled through the use of SIS fibre optic bridges and the CLS VME Crate Interface Software.

Driver

Status

Contact

Documentation

CAEN V792N CAEN charge integrating ADC, 16 channels

In use on LTB1 and SR1 for spill monitors.

Russ Berg

7.2.39.19

CAEN V820 Scaler, 32 channels

In use of LTB1 and BR1 and SR1 for spill monitors.

Russ Berg

7.2.39.19

Dynatem DPC104 3U PC/104 Card Controller for VME

Used for interfacing to absolute encoders on insertion devices.

Tony Wilson

To be added

Hytec Electronics Ltd 2508 32 Channel 16bit ADC

In use in the magnet mapping facility and several beamlines.

Russ Berg

To be added

ICS ICS 110 (CLS) 24 bit sampling ADC, 32 channels

In use on BR1 and SR1 BPMs.

Russ Berg

7.2.39.19

0MS VME58 motor controller

In use on most beamlines.

Russ Berg

To be added

Sensoray 118 8 channel 16-bit A/D for thermocouples, RDT's, strain gauges, voltage inputs, 4-20 mA, thermistors, and resistors

In use on SGM, PGM, HXMA, OSR, and magnet mapping.

Glen Wright

To be added

Struck SIS3820 Scaler - 32 channels

In use on SGM, PGM, HXMA and SM.

Glen Wright

To be added

VMIC 2536 VMIC Digital IO module, 32 channels

In use on storage ring orbit correction and insertion devices.

Russ Berg

7.2.39.19

Contact Elder Matias to learn more about control and instrumentation at the Canadian Light Source.